Heating And Cooling Your House The Grown Up Way – Pump pump my heat pump

That’s right for you rap fans Hump up to the Heat Pump, Jump up to my Heat Pump it’ll burn you baby!…Well maybe not. The idea behind a heat pump is temperature differential. When its cold outside you throw heat inside because the fluid is colder than the cold and when its hot outside you throw heat out side because the heat is hotter then the hot. Well let’s let the experts explain…

http://en.wikipedia.org/wiki/Heat_pump

According to the second law of thermodynamics heat cannot spontaneously flow from a colder location to a hotter area; work is required to achieve this. Heat pumps differ in how they apply this work to move heat, but they can essentially be thought of as heat engines operating in reverse. A heat engine allows energy to flow from a hot ‘source’ to a cold heat ‘sink’, extracting a fraction of it as work in the process. Conversely, a heat pump requires work to move thermal energy from a cold source to a warmer heat sink.

Since the heat pump uses a certain amount of work to move the heat, the amount of energy deposited at the hot side is greater than the energy taken from the cold side by an amount equal to the work required. Conversely, for a heat engine, the amount of energy taken from the hot side is greater than the amount of energy deposited in the cold heat sink since some of the heat has been converted to work.

One common type of heat pump works by exploiting the physical properties of an evaporating and condensing fluid known as a refrigerant.

A simple stylized diagram of a heat pump's vapor-compression refrigeration cycle: 1) condenser, 2) expansion valve, 3) evaporator, 4) compressor.

A simple stylized diagram of a heat pump’s vapor-compression refrigeration cycle: 1) condenser, 2) expansion valve, 3) evaporator, 4) compressor.

The working fluid, in its gaseous state, is pressurized and circulated through the system by a compressor. On the discharge side of the compressor, the now hot and highly pressurized gas is cooled in a heat exchanger called a condenser until it condenses into a high pressure, moderate temperature liquid. The condensed refrigerant then passes through a pressure-lowering device like an expansion valve, capillary tube, or possibly a work-extracting device such as a turbine. This device then passes the low pressure, barely liquid (saturated vapor) refrigerant to another heat exchanger, the evaporator where the refrigerant evaporates into a gas via heat absorption. The refrigerant then returns to the compressor and the cycle is repeated.

In such a system it is essential that the refrigerant reaches a sufficiently high temperature when compressed, since the second law of thermodynamics prevents heat from flowing from a cold fluid to a hot heat sink. Similarly, the fluid must reach a sufficiently low temperature when allowed to expand, or heat cannot flow from the cold region into the fluid. In particular, the pressure difference must be great enough for the fluid to condense at the hot side and still evaporate in the lower pressure region at the cold side. The greater the temperature difference, the greater the required pressure difference, and consequently more energy is needed to compress the fluid. Thus as with all heat pumps, the energy efficiency (amount of heat moved per unit of input work required) decreases with increasing temperature difference.

Due to the variations required in temperatures and pressures, many different refrigerants are available. Refrigerators, air conditioners, and some heating systems are common applications that use this technology.

A HVAC heat pump system

A HVAC heat pump system

In HVAC applications, a heat pump normally refers to a vapor-compression refrigeration device that includes a reversing valve and optimized heat exchangers so that the direction of heat flow may be reversed. The reversing valve switches the direction of refrigerant through the cycle and therefore the heat pump may deliver either heating or cooling to a building. In the cooler climates the default setting of the reversing valve is heating. The default setting in warmer climates is cooling. Because the two heat exchangers, the condenser and evaporator, must swap functions, they are optimized to perform adequately in both modes. As such, the efficiency of a reversible heat pump is typically slightly less than two separately-optimized machines.

:}

Everyone sells them..everyone:

http://www.searshomepro.com/hvac/options.aspx?lst=352

If you want a quote on one:

http://www2.qualitysmith.com/heat_pump

http://www.servicemagic.com/sem/category.Furnace-Central-Heating.10335.html

 or if you just want to look:

www.residential.carrier.com/products/acheatpumps/heatpumps/index.shtml

www.trane.com/Residential/Products/HeatPumps.aspx

www.rheemac.com/home_cooling_pump.shtml

www.nhec.com/residential_residentialheatpumps.php

:}

:}

Efficiently Cooling Your Home – Air conditioning the old fashioned way

I know, there are better ways to cool your house than you cool your food. Nonetheless it must be discussed for the people who just can’t do it any other way.

http://www.bobvila.com/HowTo_Library/EnergyWise_House_Energy_Efficient_Air_Conditioning-Air_Conditioning-A1629.html

EnergyWise House: Energy-Efficient Air ConditioningMany people buy or use air conditioners without understanding their designs, components, and operating principles. Proper sizing, selection, installation, maintenance, and correct use are keys to cost-effective operation and lower overall costs.

Related Showrooms

Cadet – Zonal heating solutions for your home from Cadet
Sears – Heating & Cooling Repair
Trane – Enjoy perfect heating, cooling and beyond year-round.
WholeHouseFan.com – Cool Your Home with a Whole House Fan

Air conditioners employ the same operating principles and basic components as your home refrigerator. An air conditioner cools your home with a cold indoor coil called the evaporator. The condenser, a hot outdoor coil, releases the collected heat outside. The evaporator and condenser coils are serpentine tubing surrounded by aluminum fins. This tubing is usually made of copper. A pump, called the compressor, moves a heat transfer fluid (or refrigerant) between the evaporator and the condenser. The pump forces the refrigerant through the circuit of tubing and fins in the coils. The liquid refrigerant evaporates in the indoor evaporator coil, pulling heat out of indoor air and thereby cooling the home. The hot refrigerant gas is pumped outdoors into the condenser where it reverts back to a liquid giving up its heat to the air flowing over the condenser’s metal tubing and fins.

Central Air Conditioners
Central air conditioners circulate cool air through a system of supply and return ducts. Supply ducts and registers (openings in the walls, floors, or ceilings covered by grills) carry cooled air from the air conditioner to the home. This cooled air becomes warmer as it circulates through the home; then it flows back to the central air conditioner through return ducts and registers. A central air conditioner is either a split-system unit or a packaged unit.
In a split-system central air conditioner, an outdoor metal cabinet contains the condenser and compressor, and an indoor cabinet contains the evaporator. In many split-system air conditioners, this indoor cabinet also contains a furnace or the indoor part of a heat pump. The air conditioner’s evaporator coil is installed in the cabinet or main supply duct of this furnace or heat pump. If your home already has a furnace but no air conditioner, a split-system is the most economical central air conditioner to install.Today’s best air conditioners use 30 percent to 50 percent less energy to produce the same amount of cooling as air conditioners made in the mid 1970s. Even if your air conditioner is only 10 years old, you may save 20 percent to 40 percent of your cooling energy costs by replacing it with a newer, more efficient model.But then there is new technology out there:

http://www.smarthouse.com.au/Appliances/Air_Conditioning_And_Heating/W2D2V4S2

Get rid of the bug spray because an air conditioning system that kills bugs and gives you a better night’s sleep has been revealed. The innovative new inverter wall mounted air conditioning systems, that have been scientifically proven to provide a better night’s sleep.

Samsung recently conducted extensive research in Good Sleep technology involving the Bukyung National University, Busan, Korea which revealed that a room’s temperature should change in accordance to sleep patterns, to achieve longer periods of deep sleep and ensure an optimal night’s rest. The Samsung Good Sleep 2 air conditioner control program adjusts temperature profiles to the most comfortable according to the three stages of sleep. 

http://www.smarthouse.com.au/Appliances/Air_Conditioning_And_Heating/K5J2C3C7

Smart Energy Saving Air Conditioner

By Manisha Kanetkar | Monday | 19/03/2007

Australian company Advantage Air has developed a smart reverse cycle air conditioning system that not only saves on your energy bill but is also able to be fully integrated into a home automation system.

According to Advantage Air’s Walter Kimble, all parts of the GEN III air conditioning system are designed to operate as a cohesive, integrated system making it easier for the home automation system integrator to set up. 

The system allows you, among other functions, to control the temperature of individual zones as well as program Fresh Air control.

And with sensors in each zone, the system ensures that no room is being over-heated or over-cooled, thus contributed to the product’s energy efficiency.

The Fresh Air system is an electronically controlled device that measures the temperature outside of the house. If this is cooler than that inside the house (which Advantage says is 25 percent of the time) it opens and brings cool air in. This smart function means not only do you get fresh air circulating around your house (as opposed to the same air re-circulating) but it is also energy efficient. According to the CSIRO, the GEN III is capable of energy savings of up to 38 percent or approximately $1000 a year.

 

 :}

:}

Now That Your House Is All Warm And Insulated – Whatever shall I put in it?

The big energy hogs in the house are the HVAC, The refrigerator and the water heater.

HVAC in the residentail market simply means a combine furnace and airconditioner that share the same ventilation system. but we will treat them as seperate units for easier detail:

http://www.fypower.org/res/tools/products_results.html?id=100156

Of course it would use natural gas,

 Condensing furnaces contain a second heat exchanger that condenses water vapor in the hot flue gasses, extracting additional heat. The gases are then vented directly outside through a pipe in the wall. Condensing furnaces are the most efficient on the market but they are also the most expensive. Almost all ENERGY STAR qualified furnaces are condensing models.

Efficiency Rating
Furnace efficiency is rated by annual fuel utilization efficiency (AFUE). The AFUE measures the amount of fuel converted to space heat in proportion to the amount of fuel entering the furnace. The federal minimum efficiency standard for furnaces specifies an AFUE rating of at least 78%. ENERGY STAR qualified furnaces must have a minimum AFUE rating of 90%. The most modern and efficient heating systems can achieve an AFUE of as high as 97%.

For a list of the most efficient furnaces in all output categories, visit the American Council for an Energy-Efficient Economy (ACEEE)’s guide to top-rated furnaces.

Efficiency Improvements
Some improvements that have been made to the components of furnaces in recent years are two-stage burners and higher-efficiency blower motors.

    Two-Stage Burners — When the heating demand is low, two-stage burners allow you to run your furnace at a lower burn rate most of the time, using less gas than a single stage burner. These use a special gas valve that fires the burners at either the low-heat or high-heat level. When heating needs increase, the burner fires at the high-heat level, increasing the burn rate. These burners save energy by using a smaller amount of gas when demand is low, thereby providing more even heating throughout the day.
    Fan Blower Motor — Depending on the size of the furnace, fan blower motors can use between 84 kWh/year for the smallest gas furnaces (25,000 Btu) to almost 550 kWh/year for the largest models (118,000 Btu). Some newer furnaces have an electronically commutated (ECM) fan blower motor that is more efficient than a standard blower motor. Variable-speed blower motors also have been in use in newer models. By using only the power needed for the immediate heating demand, these motors use 75% less electricity than standard motors. They also adjust to changes in air pressure among rooms, heating the space more efficiently.

 http://www.residential.carrier.com/products/furnaces/gas/index.shtml

Gas Furnaces

The smooth comfort of gas heat with the most advanced technology

For the optimal combination of gas heating and impressive energy efficiency, choose Carrier precision-engineered gas furnaces, from the innovative Infinity™ ICS with precision temperature control to the solid Comfort™ 80. The higher the AFUE rating, the more energy efficient—meaning you’ll save more money.

Infinity ICS Gas Furnace

Up to 3.5 times tighter temperature control

          Quietest furnace you can buy

  • IdealComfort™ technology
  • Lifetime heat exchanger limited warranty

96.6% AFUE

  • Variable speed blower
  • IdealHumidity
  • Lifetime heat exchanger warranty

Infinity 80 Gas Furnace

80% AFUE

  • Variable speed blower
  • IdealHumidity
  • 20-year heat exchanger warranty

Performance 93 Gas Furnace

93% AFUE

  • 4-5 speed blower
  • Enhanced humidity control
  • Lifetime heat exchanger warranty

 http://www.bryant.com/products/furnaces/index.shtml

Evolution System Plus 95s™ Furnace

  • Up to 95 AFUE
  • PerfectSense™ functionality
  • Up to 73% more consistent temperatures than single stage furnaces
  • Quietest furnace that you can buy
  • Perfect Humidity
  • Perfect Heat technology
  • Pilot-free PerfectLight ignition
  • Lifetime heat exchanger warranty

Evolution System Plus 90i™ & Plus 95i™ Furnaces

  • Up to 96.6 AFUE
  • Perfect Humidity
  • Perfect Heat technology
  • Pilot-free PerfectLight ignition
  • Lifetime heat exchanger warranty

Evolution System Plus 80v™ Furnace

  • Up to 80 AFUE
  • Perfect Humidity
  • Perfect Heat technology
  • Pilot-free PerfectLight ignition
  • 20-year heat exchanger warranty

 

 

 http://www.lennox.com/products/list.asp?type=2

 

ESTAR ICON ENERGY STAR® Product   Energy
Efficiency (AFUE)
Price
Guide*

:}

But then there is the new kid on the block: 

 

Emerging Technology

The MicroHeater, developed by the Pacific Northwest National Laboratory, could redefine the way in which homes are heated. The size of a palm, the MicroHeater is capable of combusting 4,000 to 120,000 Btu of gas per hour. They can be installed in baseboard heaters, and an array of them can efficiently heat an entire house. The MicroHeater can reduce energy loss from a typical central heating system by 45%.

 http://picturethis.pnl.gov/picturet.nsf/All/4A2LDA?opendocument

microheater.jpg

We have even talked about air conditions yet or geothermal heat pumps…geez

 

 

When Is A Concrete Block Like A Glass Window? When it comes to lousey R-Values

Believe it or not typical Concrete Products and single pane glass have the same R-Value – 1. That is because they readily give up heat because of their porus nature and in part because they are good conductors. There is a reason why castles were cold and dreary. An there is a reason why your basement is cool in the summer.

http://www.coloradoenergy.org/procorner/stuff/r-values.htm

R-Value Table

Insulation Values For Selected Materials

 Construction Materials

Concrete Block 4″   0.80
Concrete Block 8″   1.11
Concrete Block 12″   1.28
Brick 4″ common   0.80
Brick 4″ face   0.44
Poured Concrete 0.08  

I should mention that the poured concrete number is by the inch. It takes no math wiz to see that 20 inches of typical concrete still is an R-value of slightly less than 1.

But you ask, “Mr. CES Man why is that important?” It is important in the Residential Market because a lot of us have basements made out of concrete, masonary block or a combination of the two.

According to the government:

U.S. Department of Energy – Energy Efficiency and Renewable Energy

A Consumer’s Guide to Energy Efficiency and Renewable Energy

Basement Insulation

A properly insulated basement can help reduce your energy costs. However, basement walls are one of the most controversial areas of a house to insulate and seal. You need to carefully consider the advantages and disadvantages, not to mention moisture control.

Before insulating or deciding whether to add insulation to your basement, first see our information about adding insulation to an existing house or selecting insulation for new home construction if you haven’t already.

U.S. Cities R-10* R-2-**
Buffalo, NY $350 $390
Minneapolis, MN $400 $450
St. Louis, MO $250 $290

*Such as 2 to 3 inches of exterior foam insulation.
**Such as with most insulated concrete forms.

Annual Energy Savings

The energy cost savings of basement wall insulation vary depending on the local climate, type of heating system, fuel cost, and occupant lifestyle. Typical annual cost savings by R-value in a few U.S. cities are provided in the table above for a 1,500 square-foot home with a conditioned basement heated by natural gas ($0.72/therm).

Advantages and Disadvantages

In most cases, a basement with insulation installed in the exterior basement walls should be considered a conditioned space. Even in a house with an unconditioned basement, the basement is more connected to other living spaces than to the outside. This connection makes basement wall insulation preferable to insulating the basement ceiling.

Compared to insulating the basement ceiling, insulating basement walls has the following advantages:

  • Requires less insulation (1,350 square feet of wall insulation for a 36 x 48-foot basement with 8-foot walls, compared with 1,725 ceiling)
  • More easily achieves continuous thermal and air leakage boundaries because basement ceilings typically include electrical wiring, plumbing, and ductwork.
  • Requires little, if any, increase in the size of the heating and cooling equipment. The heat loss and air leakage through the basement ceiling is similar to that through the exterior walls of the basement.

These are some other advantages of insulation on exterior basement walls:

  • Minimizes thermal bridging and reducing heat loss through the foundation
  • Protects the damp-proof coating from damage during backfilling
  • Serves as a capillary break to moisture intrusion
  • Protects the foundation from the effects of the freeze-thaw cycle in extreme climates
  • Reduces the potential for condensation on surfaces in the basement
  • Conserves room area, relative to installing insulation on the interior.

:}

Leave it to the Bush administration to say that insulation is controversial. If you are building a new home there is not a doubt that you should insulate the exterior basement walls. In fact if you are building a pad style house, you should insulate underneath the pad with some kind of insulative mixed cement. I am not sure the whole pad needs to be of that type concrete. It is expensive but if you can afford it can’t hurt.

http://www.askthebuilder.com/N2-Basement_Insulation.shtml

Mr. Builder Man makes the point that the only place to insulate in the basement is on the walls. He adds:

 Because your basement walls are conducting cold into your basement via the cold ground outside, it might be worthwhile to add insulation over your exposed masonry foundation. You can choose to use closed-cell foam or fiberglass if you choose. But be sure you check with your local building department as some insulations that are flammable – such as closed cell foam – must be covered with drywall or other approved material to prevent rapid fire/flame spread.

:}

He finishes on a note that warms the heart of a die hard conservationist:

I would also inspect the juncture between the wood framing and the top of the concrete foundation. Do this on a windy day and try to feel for air leaks. Air infiltration can be a major drain on your heating budget. Pack insulation in any cracks you discover or caulk them to stop air flow.

All these people agree:

www.homeimprovementweb.com/information/how-to/basementinsulation.htm

www.homeenvy.com/db/0/750.html

www.owenscorning.com/around/insulation/fallpromo/DIY-Basement.asp

www.doityourself.com/scat/basementinsulation

www.thisoldhouse.com/toh/asktoh/question/0,,396510,00.html

www.state.mn.us/mn/externalDocs/Commerce/Basements_110602012856_Basement.pdf

www.builtgreen.org/articles/0208_mold.htm

I prefer a radical approach hire a Backhoe and dig out the dirt around your basement. Then you can apply ridgid waterproof R Board to the outside of the basement. Then you can backfill with gravel for drainage and tap down some dirt. Your house will thank you for ever. For those people that have a house already resting on a pad, you have one heck of a problem on your hands. 

:}

For Those Of You Who Can’t Give Up Their Windows – Energy efficient windows are a must

The problem with this topic is everyone is in the window business or the window advice business. It’s like ceiling fans, the makers are everywhere, they make tons of products, and their are millions of opinions about them. So I will try to be simple and to the point. Anyway you cut it single pain (oh sorry) double hung windows should be a thing of the past

http://www.efficientwindows.org/lowe.cfm

Window Technologies: Low-E Coatings

Low-emittance (Low-E) coating are microscopically thin, virtually invisible, metal or metallic oxide layers deposited on a window or skylight glazing surface primarily to reduce the U-factor by suppressing radiative heat flow. The principal mechanism of heat transfer in multilayer glazing is thermal radiation from a warm pane of glass to a cooler pane. Coating a glass surface with a low-emittance material and facing that coating into the gap between the glass layers blocks a significant amount of this radiant heat transfer, thus lowering the total heat flow through the window. Low-E coatings are transparent to visible light. Different types of Low-E coatings have been designed to allow for high solar gain, moderate solar gain, or low solar gain.

 Double-Glazed with High-Solar-Gain Low-E Glass

 This figure illustrates the characteristics of a typical double-glazed window with a high-transmission, Low-E glass and argon gas fill. These Low-E glass products are often referred to as pyrolitic or hard coat Low-E glass, due to the glass coating process. The properties presented here are typical of a Low-E glass product designed to reduce heat loss but admit solar gain. High solar gain Low-E glass products are best suited for buildings located in heating-dominated climates. This Low-E glass type is also the product of choice for passive solar design projects due to the performance attributes relative to other Low-E glass products which have been developed to reduce solar gain.

In heating-dominated climates with a modest amount of cooling or climates where both heating and cooling are required, Low-E coatings with high, moderate or low solar gains may result in similar annual energy costs depending on the house design and operation. While the high solar gain glazing performs better in winter, the low solar gain performs better in summer. Low solar gain Low-E glazings are ideal for buildings located in cooling-dominated climates. Look at the energy use comparisons under Window Selection to see how different glazings perform in particular locations. (these products can come with Krypton gas but are more expensive)
glazing_sputtered.jpg

Double-Glazed with Moderate-Solar-Gain Low-E Glass

 This figure illustrates the characteristics of a typical double-glazed window with a moderate solar gain Low-E glass and argon gas fill. These Low-E glass products are often referred to as sputtered (or soft-coat products) due to the glass coating process. (Note: Low solar gain Low-E products are also called sputtered coatings.) Such coatings reduce heat loss and let in a reasonable amount of solar gain and are suitable for climates with both heating and cooling concerns. In heating-dominated climates with a modest amount of cooling or climates where both heating and cooling are required, Low-E coatings with high, moderate or low solar gains may result in similar annual energy costs depending on the house design and operation. Look at the energy use comparisons under Window Selection to see how different glazings perform in particular locations. glazing_pyrolitic.jpg

Double-Glazed with Low-Solar-Gain Low-E Glass
(Spectrally Selective)

This figure illustrates the characteristics of a typical double-glazed window with a low solar gain Low-E glass and argon gas fill. These Low-E products are often referred to as sputtered (or soft-coat) due to the glass coating process. (Note: Moderate solar gain Low-E products are also called sputtered coatings.) This type of Low-E product, sometimes called spectrally selective Low-E glass, reduces heat loss in winter but also reduces heat gain in summer. Compared to most tinted and reflective glazings, this Low-E glass provides a higher level of visible light transmission for a given amount of solar heat reduction.

Low solar gain Low-E glazings are ideal for buildings located in cooling-dominated climates. In heating-dominated climates with a modest amount of cooling or climates where both heating and cooling are required, Low-E coatings with high, moderate or low solar gains may result in similar annual energy costs depending on the house design. While the high solar gain glazing performs better in winter, the low solar gain performs better in summer. Look at the energy use comparisons under Window Selection to see how different glazings perform in particular locations.

Variants on low solar gain Low-E coatings have also been developed which lower solar gains even further. However this further decrease in solar gains is achieved by reducing the visible transmittance as well – such coatings, which may appear slightly tinted, are best suited for applications where cooling is the dominant factor and where a slightly tinted effect is desired.

glazing_ss.jpg 

Here are all the people and places that care:

www.AndersenWindows.com

www.HomeDepot/Installations.com     

www.bobvila.com/HowTo_Library/Understanding_Low_e_Window_Coatings-Residential-A2077.html

www.askthebuilder.com/097_LowE_Glass_-_It_Really_Works_.shtml

www.energystar.gov/index.cfm?c=windows_doors.pr_anat_window 

www.milgard.com/getting-started/energy-efficiency.asp

www.pellacommercial.com

www.tva.apogee.net/res/rewlowe.asp

www.ases.org/askken/2005/05-21.htm

www.ifenergy.com/50226711/advantage_lowe_windows.php

:}

:}

Superinsulation Can Mean Many Things – But it is all good

The term was started in the “new build” industry but it has since migrated to the built environment as well. The general concept is that there is no such thing as TOO MUCH insulation in the residential market. It can provide living space that “sips” energy.

http://en.wikipedia.org/wiki/Superinsulation

The term “superinsulation” was coined by Wayne Schick at the University of Illinois at Urbana-Champaign. In 1976 he was part of a team that developed a design called the “Lo-Cal” house, using computer simulations based on the climate of Madison, Wisconsin. The house was never built, but some of its design features influenced later builders.

:}

If I am not mistaken he was getting his concepts from those used in much colder climates, like Sweden and Denmark where they value their resources…actually where they value life and family in general.

http://www.newscientist.com/article/mg12917595.400-the-house-that-came-in-from-the-cold-houses-designed-withenergy-efficiency-in-mind-are-more-pleasant-to-live-in-less-harmful-totheenvironmentand-need-not-be-expensive-to-build-.html

The house that came in from the cold:

Houses designed with energy efficiency in

mind are more pleasant to live in, less

harmful to the environment-and need not be expensive to build.

09 March 1991

Buildings use about half the energy industrialized countries consume. Much of it could be saved, conserving resources and reducing our contribution to global warming. Energy efficient housing has already been tried and tested in several countries, with some success.

Between 1975 and 1977, building researchers and designers in North America and Scandinavia pioneered a radically new approach to reducing heat loss from buildings, now called ‘superinsulation’. Conventional buildings lose most of their heat by simple air leakage. Superinsulated buildings are firmly sealed against draughts, with a controllable ventilation system to provide fresh air in winter. In Sweden, all new houses must by law have fewer than three air changes per hour, tested at a pressure difference between inside and outside of 50 pascals. In superinsulated houses this figure is often brought below 1 air change per hour, while in a typical British house there are 10 air changes per hour under the same conditions (see Table 1).

By the late 1980s, there were more than 100 000 superinsulated dwellings in North America and Scandinavia, where most houses are built of timber. But the problems of adapting these techniques to houses built of brick and concrete prevented superinsulation being applied on any large scale in Europe until the early 1980s. Most of Britain’s houses-new and old-are put together with little regard to energy efficiency . In the rest of Europe, however, the technique is beginning to take root.

The Netherlands now has more than 1000 superinsulated houses.

:}

The important thing to remember here is that these are not just superinsulated living spaces, they are TIGHT spaces as well. Just throwing insulation at the problem is a good thing but tight construction techniques are important too. Little things like caulking in existing homes can accomplish much the same thing. Another thing to pull out of the construction “speak” above. It takes 3 turnovers in the atmosphere in a living space to keep humans alive. Also in tight spaces smells and moisture can build up so adequate ventalation is critical as is a carbon monoxide/dioxide detector.

Also note that most of these houses contain backup, many times “unconventional” heating sources. Though the idea was that all of the cooking, human waste heat, water heating etc. would handle heating in the winter.  And that ventaltion could handle the cooling in the summer. Most buyers wanted backup heating and cooling as a psychological reassurance. Often times a geothermal heat pump served as a device that could supply both heating and cooling.

Then there is also the Passive House movement:

http://en.wikipedia.org/wiki/Passive_solar_building_design

Passive solar buildings aim to maintain interior thermal comfort throughout the sun’s daily and annual cycles whilst reducing the requirement for active heating and cooling systems. Passive solar building design is one part of green building design, and does not include active systems such as mechanical ventilation or photovoltaics, nor does it include life cycle analysis.

http://www.solarserver.de/lexikon/passivhaus-e.html

Passive Building

From the energy-saving point of view, passive buildings are most advanced, and when considering the involved technology they can be constructed almost anywhere

https://www.rmi.org/images/PDFs/Energy/E95-28_SuperEffBldgFrontier.pdf

www.oikos.com/library/energy_outlet/passive_solar.html

Basic Ideas in

Passive Solar Buildings

Natural Forces At Work For You
In any climate, a building can make use of free heat from the sun. An elementary passive solar heating concept is letting in the sunshine with windows, then keeping the resulting heat inside with insulation and thermal mass. The goal in passive solar building is the optimal balance of mass, glass, and insulation for a particular site and house design. A well-designed solar home in Oregon’s Williamette Valley can get up to 30 percent of its winter heating needs met at no cost.

Passive Cooling

Passive cooling requires correct placement of windows, proper shading of windows by trees or constructed shade, light-colored roofs and walls to reflect heat, nighttime ventilation, and thermal mass to prevent overheating in hot, sunny weather. Large west-facing glass areas usually present a risk of unwanted summer afternoon heat gains. Air-conditioning is unnecessary in the maritime Northwest, if the house is properly designed.

Choose The Right Building Site

The more southern exposure, the better the site for passive solar. A steep north-facing slope, or large trees or other buildings in the wrong places will cut back on your solar window. Protective berms, natural slopes, and thick tree cover to the north side block cold winter winds and help create a warmer microclimate around your house. See the Energy Outlet handout on landscaping and house siting.

Let The House Face The Sun

It is very important to orient the long axis of the house east-west, so that as much wall and roof length faces directly south as possible. The most livable homes group the kitchen and dining room to the east, for morning light. Clerestory windows and dormers can bring winter light into otherwise dark areas of the house (minimize skylight use). Use a solar path chart to design a building so that low winter sun shines in and high summer sun is blocked by effective use of windows, overhangs and shade.

South-Facing, High Quality Windows

Passive solar houses have large window areas on the south side where the sun comes from, and minimal windows on the north side. Some sites will suggest minimal west-facing windows (SHGC<.40) as well. Window specifications should be tuned for the window location; use softcoat LowE (lower SHGC) on north, west, and possibly east-facing glazing, and hardcoat LowE, or maybe uncoated windows (.55 or higher SHGC) on south-facing glazing. You should be able to get windows with U-values below 0.32 without much difficulty by using warm-edge glazing spacers, LowE coatings, and inert gas fills.

Superinsulate, Build Tight, Ventilate Right

High R values and minimal air leakage are the most important factors in building any low-energy house. The Oregon Energy Code is a minimum, not a maximum. There is no such thing as too much insulation, only practical difficulties in implementation! Blower door test to verify house tightness. Invest in a high performance ventilation system; an air to air heat exchanger recovers the heat in exhausted ventilation air.

:}

This however can lead you into exotic discussions of equipment and materials which cause people to go to sleep. As the forward on one passive building book put it, “If you have never read about superinsulation before this could be a tough read”. These discussions do not include rammed earth homes:

http://www.rammedearthhomes.com/

or houses made of bales of hay or straw,

which would baffle most people. Bottom line is that if you can get R value 60 in your unused attic or a radiant barrier and R 30 if it is being used for storage. You will save BUNCHES of money quickly. I would add the small point that adequate ventilation of the attic space during the summer is important too. Also if you stuff R 15 in your walls anyway you can you will exceed probably 50% of the housing stock in the USA.
:}

Residential Solar Photovoltaics Are Affordable – Now is the time to buy

I think this story tells itself:

http://www.thedailygreen.com/green-homes/eco-friendly/evergreen-solar-panels-460608

6.19.2008 12:38 PM

More Efficient, Lower

Impact Solar Panels Developed

Evergreen Solar Announces

Improved Solar Technology

Massachusetts-based Evergreen Solar has announced a new line of high efficiency solar panels this month.

Called the ES-A Series, the 200, 205 and 210 W solar panels are made with Evergreen’s proprietary “String Ribbon” technology. Inside the company’s custom furnaces, a set of special parallel strings are pulled through a molten pool of silicon. A thin “ribbon” forms between strings as the silicon cools. The ribbon is then cut into wafers, which are fashioned into solar cells.

According to Evergreen, the carbon footprint of these new panels is up to 50% smaller than those of competitors, and they have a quicker energy payback — reportedly as fast as 12 months for installed panels. This last point is particularly exciting, since the amount of energy required to make solar panels has long been a bone of contention among critics of the technology.

Back in the late 90s, energy paybacks for solar panels were as high as seven years. Today, they are often reported as “1-5 years.”

Evergreen says it will begin production of its new panels by July. They will be built in its new manufacturing plant in Devens, Massachusetts, where the workforce has reportedly swelled from 300 to 1,000.

The company says its final products will include longer cables for easier installation, new clickable connectors and a new low voltage configuration for greater flexibility.

:}

:}

http://www.boston.com/news/science/articles/2008/06/18/evergreen_solar_gets_2_contracts_worth_about_600m/

Evergreen Solar Gets

2 contracts worth about

$600M

 June 18, 2008

MARLBORO, Mass.—Solar panel producer Evergreen Solar Inc. said Wednesday it signed two sales contracts extending through 2012 with a combined value of about $600 million.

The contracts are with White River Junction, Vt.-based groSolar and Germany’s Wagner & Co Solartechnik GmbH, which designs and installs solar electric and hot water systems.

The solar panels for the new contracts will be made in Evergreen’s Devens, Mass., facility starting in July.

Evergreen Solar said its contractual backlog now stands at $1.7 billion.

Shares jumped $1.37, or 13.4 percent, to $11.56 in after-hours trading. The stock closed at $10.24 in the regular session.

Every Engineer Must Become A Social Engineer – If the residential housing market is to make in modern times

For instance the home refrigerator must be totally redesigned. NOT made more efficient but redesigned. Light tunnels need to totally replace windows. The HOUSE itself needs to be completely rethought.

http://www.spacedaily.com/reports/Energy_Housing_and_Recycling_Advances_To_Be_Unveiled_At_TMS_2008_Annual_Meeting_999.html

Energy, Housing and

Recycling Advances To Be

 Unveiled At TMS

2008 Annual Meeting


Energy efficiency is also one of the problems with today’s housing. Stephen Lee, professor in the School of Agriculture at Carnegie Mellon University in Pittsburgh, Pennsylvania, says American methods of homebuilding are not responding to global and regional changes.

by Staff Writers
Warrendale PA (SPX) Dec 18, 2007
Energy, housing and recycling solutions for the 21st century are among the research topics that will be presented at the TMS 2008 Annual Meeting and Exhibition, March 9-13, in New Orleans, Louisiana, USA. These topics are part of the “Materials and Society” vein of the meeting, which focuses on engineering solutions to some of society’s most perplexing problems.

“Engineers solve problems, make things happen and enhance the quality of life on this planet. This has always been a constant; however what has changed over time has been the needs of society and how engineers have responded to those needs,” according to Diran Apelian, Ph.D., Director of the Metal Processing Institute in Worcester, Massachusetts, and chair of the Materials and Society program.

“With 20 percent of the world population living in absolute poverty; 18 percent of the population lacking access to safe drinking water; 40 percent having no access to sanitation; energy consumption increasing at a higher rate than population growth; and healthcare needs and expectations increasing out of sync with the cost of health care delivery; there is no doubt that the engineer for the 21st century has to be a social scientist.”

One such challenge is finding clean, alternative sources to produce energy at economically, competitive rates given the world’s demand for energy, and global warming. Tomas Diaz De La Rubia of the Lawrence Livermore National Laboratory in Livermore, California, will discuss the efforts to date to develop new materials for energy applications in his presentation, “Energy Sources for the 21st Century – Implications and Challenges.”

“Meeting the growth in energy demand while mitigating climate change will demand new energy sources beyond fossil fuels, such as solar, nuclear and, ultimately, fusion.” Dr. Diaz says these new materials must be highly efficient, safe and reliable in extreme environments.

Energy efficiency is also one of the problems with today’s housing. Stephen Lee, professor in the School of Agriculture at Carnegie Mellon University in Pittsburgh, Pennsylvania, says American methods of homebuilding are not responding to global and regional changes.

“Our houses of today are not meeting the needs of the users, nor are they performing as good global citizens.” Professor Lee believes applying industrial engineering principles to the housing delivery process could solve these problems. In his presentation, “Housing for the 21st Century – Design, Technology and Construction,” he will use the 2007 Carnegie Mellon Solar Decathlon house as a case study to illustrate process solutions.

:}

Reengineering is actually pretty simple
:}

http://bita.hdinc.com/en/art/?132

But “resizing” is an inadequate definition for reengineering. Classic reengineering is re-deciding the way we do business based on the best options available to us at that time. It is not driven fundamentally by people, but by changes in technology that occur over time.

Take the example of our CEO’s house. Sixty years ago a young accountant told his fiancee, “I’ll build us the best home money can buy.” Then he worked with an architect to design the house. Some of the decisions he made were about which plumbing and lighting options to install. He and his architect looked at all the options available in the 1930’s and chose the best ones. So they “engineered” the house. Sixty years later, Dutch (Holland) and his wife, Jan, sat down with an architect to consider some changes. Once again they had to make decisions about plumbing and lighting. This time they had an entirely different set of options to look at. Based on these new options, they “reengineered” the house and put in plumbing and lighting systems not available to the original builder. We would expect that someone purchasing the house in 2020 will probably make different choices … ones that Dutch and Jan don’t — can’t — know about.

:}

AHHHHH home sweet home

:}

http://www.solardecathlon.org/homes_gallery.html#carnegie

cornell.jpg

penn.jpg 

aandm.jpg

The last one is my favorite – I love personal windmills…

Back To Community Energy Systems’ Roots – The residential housing market

This blog has sometime drifted pretty far afield from its mission which is to move the residential housing market away from the hydrocarbon economy. The Religion and the Environment posts and the Presidential Candidates post immediately come to mind so for the next 8 – 10 days I plan on spending all our time looking at the specifics of energy conservation and energy generation in the housing market

.

It’s the honest to god truth – if your air conditioner is more than 10 years old…recycle it. The piece below is not necessarily a product endorsement. Every manufacture-er from Train to Toshiba is “sipping” electricity and natural gas. I wish everyone would go with geothermal then we would be blending in as a species and not standing out.

 

http://enewschannels.com/2007/11/29/enc2308_194045.php

Style Crest Advances Efficiency for Heating and A/C

Thu, 29 Nov 2007 19:40:45 -0800 PST by Tabitha Berg


Smart Components(TM) from Style Crest(R) Offer Advanced Technology and Superior Efficiency in Manufactured Housing Heating and Air ConditioningFREMONT, Ohio — Style Crest, Inc. (www.stylecrestproducts.com) has combined state-of-the-art technology and superior product engineering to produce the industry benchmark in manufactured home HVAC equipment. In addition to an extensive range of HVAC products, the Smart Components line includes 13 SEER air conditioning condensers with Micro Channel technology. As part of the Smart Components line, Style Crest’s new 13 SEER Air Conditioning Condenser Units bring ground-breaking Micro Channel technology to the industry. Micro Channel technology replaces traditional copper tube/aluminum fin heat exchangers with all aluminum multi-path, parallel-flow tubes and enhanced fins. Micro Channel is the new technology that is more efficient, resulting in a unit that is up to 40% smaller, 30% lighter and requires up to 50% less refrigerant. This combination allows for easier installation and maintenance and has up to 7 times the corrosion resistance of conventional units. By reducing the environmental impact, the smaller refrigerant charge creates additional value. Furnaces in the Smart Components line are air conditioner and heat pump ready. A built-in coil cabinet provides for the simple installation of an air conditioning evaporator without the moisture problems associated with an uncased coil. Electric furnaces feature sound absorbing insulation for even quieter operation.Evaporator coils from the Smart Components line will work with any manufactured housing-type furnace, and are ARI rated for use with a variety of manufacturers’ condensers. However, when used in combination with a Micro Channel condenser unit, these coils deliver even greater performance.

Offered in nominal 2 through 5 ton capacities, these coils offer true 13 SEER efficiency.Distributors, contractors, retailers, and homeowners appreciate the higher performance, easier installation, and lower maintenance of the Smart Components line of HVAC equipment, offered by Style Crest. In both new construction and replacement applications, Smart Components deliver engineered solutions to the manufactured housing industry. Smart Components – Great Ideas Individually…Together They’re Brilliant!Style Crest is a vertically integrated manufacturer, distributor and installer of products for the housing industry. With more than 35 years of experience and proven performance, Style Crest provides the advantages of service and products for the evolving housing construction marketplace. For more information www.stylecrestproducts.com 

Technorati Tags: , , ,